Product Details:
Place of Origin: China
Certification: CE, ISO13485
Model Number: PA-500
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Delivery Time: 5-7 days
Payment Terms: T/T, Western Union
Supply Ability: 200 units per month
Contact Now
Detailed Product Description
Properties: Medical Materials & Accessories Type: General Medical Supplies
Oem: Available Certification: CE FDA ISO13485
Name: Medical Ventilator Machine Usage: ICU Equipment
High Light:

medical consumable products

,

disposable medical devices

ICU Equipment CE Approved Medical Ventilator PA-500

Breathing Mode: IPPV, SIPPV, IMV, SIMV, PEEP, Manu, Sigh and so on;
Tidal Volume Adjustment 50~1200ml
Ventilation Capacity per Minute ≥ 18L
Oxygen Concentration < 45%
Ventilator Conformance ≤ 30mL/kpa
Respiratory Rate 6~60/m
I/E Ratio: 1: 1.5, 1: 2.0, 1: 2.5, 1: 3.0;
Maximum Safe Pressure ≤ 6.0kPa
(Ptr) Range -0.4~1.0kPa
Transfer Time from Controlled to Assistant Respiration 6s
Air Flow Adjustment 1~12times /m
PEEP 0.1~1.0kPa
Sigh Volume: 150% of tidal volume
Oxygen Consumption: ≤ 1.5mPa change in pressure after 1-hour operation of oxygen cylinder of 12250kPa/40

 

 

Breathing Mode IPPV, SIPPV, IMV, SIMV, PEEP, Manu, Sigh and so on;
Tidal Volume Adjustment 50~1200ml
Ventilation Capacity per Minute ≥18L
Oxygen Concentration <45%
Ventilator Conformance ≤30mL/kpa
Respiratory Rate 6~60/m
I/E Ratio: 1:1.5, 1:2.0, 1:2.5, 1:3.0;
Maximum Safe Pressure ≤6.0kPa
(Ptr) Range -0.4~1.0kPa
Transfer Time from Controlled to Assistant Respiration 6s
Air Flow Adjustment 1~12times /m
PEEP 0.1~1.0kPa
Sigh Volume: 150% of tidal volume
Oxygen Consumption:≤1.5mPa change in pressure after 1-hour operation of oxygen cylinder of 12250kPa/40L.